ADJUSTABLE POSITIVE PULSES FOR ENHANCED COATING PROPERTIES
The PLASMATEC Ap, the unipolar pulsed DC power supply is a switch-mode power supply for particularly demanding arc-sensitive processes. Like the other PLASMATEC devices it is a true current source using CFC-technology. The PLASMATEC Ap alternatively provides a DC or an unipolar pulsed DC current / voltage at an output frequency of 76 kHz. Only the PLASMATEC Ap has an optional and fully active adjustable reverse pulse mode with arc detection. The power supply is available with 6 and 12 kW. In parallel mode the 12 kW unit can increase the power up to 24 kW. The digital regulated input of current, voltage and power makes it very precise.
Like other PLASMATEC power supplies the PLASMATEC Ap has high power density, extremely low stored output energy and a sophisticated, flexible, adjustable arc management. Its great robustness makes it ideal for industrial applications or research.
Our PLASMATEC Ap series
Article number | NDCR1702F01001 |
---|---|
Input | |
Input voltage | 3 x 400 V AC +/- 10 % |
Nominal frequency | 50 / 60 Hz +/- 5 % |
Max. input current | 12 A |
Output | |
Adjustable output voltage | 0 – 1000 V |
Nominal output voltage (at max.power) [Vav] | 500 - 1000 V |
Cycle duration | 13 μsec |
Frequency of output voltage | 76.923 kHz |
Negative Pulse (Power pulse) = Tp | |
Regulation | U, I, P |
Adjustable pulse width | 1 μsec ... 11.5 μsec |
Pulsed nominal output current | 12 A at 500 V / 6 A at 1000 V |
Pulsed nominal output power | 6 kW |
Positive Pulse (reverse pulse) = Rp | |
Regulation | U, P |
Pulse width | 0.5 μsec ... 11.0 μsec |
Pulsed nominal output current | 12 A at 500 V / 6 A at 1000 V |
Pulsed nominal output power | 6 kW |
Ignition voltage [Vig] | 1200 … 1400 |
Rise up time of ignition voltage | < 1 μsec / kV |
Arc recognition | < 1 μsec |
Passive arc energy | << 3 mJ |
Article number | NDCR1703F01001 |
---|---|
Input | |
Input voltage | 3 x 400 V AC +/- 10 % |
Nominal frequency | 50 / 60 Hz +/- 5 % |
Max. input current | 23 A |
Output | |
Adjustable output voltage | 0 – 1000 V |
Nominal output voltage (at max.power) [Vav] | 500 - 1000 V |
Cycle duration | 13 μsec |
Frequency of output voltage | 76.923 kHz |
Negative Pulse (Power pulse) = Tp | |
Regulation | U, I, P |
Adjustable pulse width | 1 μsec ... 11.5 μsec |
Pulsed nominal output current | 24 A at 500 V / 12 A at 1000 V |
Pulsed nominal output power | 12 kW |
Positive Pulse (reverse pulse) = Rp | |
Regulation | U, P |
Pulse width | 0.5 μsec ... 11.0 μsec |
Pulsed nominal output current | 12 A at 500 V / 6 A at 1000 V |
Pulsed nominal output power | 6 kW |
Ignition voltage [Vig] | 1200 … 1400 |
Rise up time of ignition voltage | < 1 μsec / kV |
Arc recognition | < 1 μsec |
Passive arc energy | << 3 mJ |
General Technical Data
Connection in parallel | up to 10 units |
Synchronization | up to 20 units |
Interfaces | I/O interface / RS232 interface |
more interfaces as option possible | |
Dimensions (H x W x D) | 133.35 x 482.6 x 600 (725 inklusive Stecker) mm |
3HU x 19” x 600 mm |