![]() | A hybrid UPS consists of an AKKUTEC, a battery system and a C-TEC P with ultra capacitors. In combination with the battery system, the AKKUTEC provides the desired long-term buffering, e.g. in fire alarm systems, gas warning systems, mains transfer stations and other critical infrastructures. In addition, a C-TEC P is integrated in the hybrid UPS from J. Schneider, with which several safe switching operations with inrush current peaks of up to 25 A are also possible.
Due to the various combination options of AKKUTEC and C-TEC P units with batteries in different capacities, the hybrid UPS can be combined according to the customers' requirements.
You can find a selection of the different components and possible combinations here
|
---|
for Example tor the use in fire alarm systems, automatic openable vents for smoke and heat, speech alarm systems |
Accumulators are not in included in the delivery and must be ordered separately |
All cabinet versions with 3 A output voltage are epuipped with fuse boards with 5 fuses. |
All cabinet versions above 3 A output voltage are equipped with fuse boards with 10 fuses. |
All cabinet version include a temperature sensor for voltage tracking. |
Battery fuse up to 12 A version included on fuse board. |
Norms: | for the use in automatic fire alarm sytems |
---|---|
DIN EN 54-4 | energy supply systems for fire alarm systems / speech alarm systems |
DIN EN 12101-10:2006-01 DIN EN 12101-10:2009-07 | energy supply systems in smoke and heat venting systems |
VdS 2541:1996-12 | energy supply constructions |
VdS 2203:2001-03 | software controlled system parts |
VdS 2344:2005-12 | procedure and qualification directives |
AKKUTEC 2401 C | *AKKUTEC 2412C | |||
---|---|---|---|---|
![]() | ![]() | ![]() | ||
input voltage | 230V | 230V | 230V | |
output voltage | 24V 2,4A | 24V 3A | 24V 12A | |
suitable for battery | battery 12-2,4Ah | each 2 battery 7,2 - 26Ah | each 2 battery 12 - 65Ah |
AKKUTEC 1203P | *AKKUTEC 2403P | AKKUTEC 4801P | AKKUTEC 1208P | AKKUTEC 2405P | AKKUTEC 4803P | AKKUTEC 1210P | |
---|---|---|---|---|---|---|---|
![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |
input voltage | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V |
output voltage | 12V 3A | 24V 3A | 48V 3A | 12V 5A | 24V 5A | 48V 3A | 12V 10A |
suitable for Akku | from 7,2 - 80Ah | from 7,2 - 40Ah | from 7,2 - 18Ah | from 7,2 - 80Ah | from 7,2 - 40Ah | from 7,2 - 18Ah | from 7,2 - 40Ah |
AKKUTEC 4810P | AKKUTEC 4810P | *AKKUTEC 2412P | *AKKUTEC 2412P | AKKUTEC 2420P | AKKUTEC 2420P | *AKKUTEC 2424P | |
---|---|---|---|---|---|---|---|
![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |
input voltage | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V |
output voltage | 48V 10A | 48V 10A | 24V 12A | 24V 12A | 24V 20A | 24V 20A | 24V 24A |
suitable for battery | from 7,2 - 18Ah | from 7,2 - 85Ah | from 7,2 - 40Ah | from 7,2 - 170Ah | from 7,2 - 40Ah | from 7,2 - 40Ah | from 7,2 - 170Ah |
![]() | additional safety board with 5 additional fuses additional safety board with 10 additional fuses |
---|
drive modul for signal transmitter/blinking light
optical signal transmitter, manufacturer Pfannenberg type PB 2005, 5 Joule blinking energy 24V DC, 0,25 A
acoustic signal transmitter, manufacturer Pfannenberg type PA 100, 100dB(A) noise level, 24V DC, 40 mA
![]() | ![]() | ![]() | ![]() | ![]() |
AC-UPS | DC-UPS | AC-UPS | AC-UPS | DC-UPS |
20kVA | 24V, 5A | 60kVA | 60kVA | 160A |
1h back-up time | redundant | input 500V for IT networks | input 500V for IT networks | for 13-cellular lead-acid battery + inverter |
IP 54 extendable | with distribution | 15 min back-up time | 15 min back-up time | 1,5kVA, 230V for nuclear facilities |