Input- / Output-connectors / cables

For the high voltage power supplies up to 10kV and up to 10kW no special mains input plugs are needed. On these devices, power input cable is connected directly to the feed-through terminals of the line filter.

Article Number
Usable for
Cable Typ
Cable Length
CAPTEC
GLOWTEC
VAPTEC
(Vout < 10kV)
(Pout <= 10kW)


 

Ölflex 5 x 4mm2

 


No spezial plug required.
Directly connected at the
terminals of the line filter.
NDC70739F01002



 

LIPTEC or for
CAPTEC

GLOWTEC
VAPTEC
(Vout > 10kV)
(Pout = 10kw)


--Harting plug 4mm2-
NDC41117F02002

Ölflex 5 x 4mm2

2 meterHarting plug 4mm2open
NDC41117F04002Ölflex 5 x 4mm24 meterHarting plug 4mm2open
NDC41117F06002Ölflex 5 x 4mm26 meterHarting plug 4mm2open
NDC41117F08002Ölflex 5 x 4mm28 meterHarting plug 4mm2open
NDC41117F10002Ölflex 5 x 4mm210 meterHarting plug 4mm2open
NDC71018F01002



CAPTEC

GLOWTEC

VAPTEC

(Vout > 10kV)
(Pout >= 20kw)

--Harting plug 6mm2open
NDC41117F02002Ölflex 5 x 6mm22 meterHarting plug 6mm2open
NDC41117F04002Ölflex 5 x 6mm24 meterHarting plug 6mm2open
NDC41117F06002Ölflex 5 x 6mm26 meterHarting plug 6mm2open
NDC41117F08002Ölflex 5 x 6mm28 meterHarting plug 6mm2open
NDC41117F10002Ölflex 5 x 6mm210 meterHarting plug 6mm2open

Output- Connectors / cables

For the high voltage power supplies up to 10kV and up to 10kW no special mains input plugs are needed. On these devices, power input cable is connected directly to the feed-through terminals of the line filter.

Article Number
Usable for
Cable TypCable Length
3405.3



 



CAPTEC

GLOWTEC

VAPTEC
from NHCR => universal
(up to max. 10kV)







--ODU-socket 4mm-
NHC41001E02001RG2132 meterODU-socket 4mmopen
NHC41001E04001RG2134 meterODU-socket 4mmopen
NHC41001E06001RG2136 meterODU-socket 4mmopen
NHC41001E08001RG2138 meterODU-socket 4mmopen
NHC41001E10001RG21310 meterODU-socket 4mmopen
NHC41001E12001RG21312 meterODU-socket 4mmopen
NHC41001E14001RG21314 meterODU-socket 4mmopen
NHC41001E16001RG21316 meterODU-socket 4mmopen
NHC41001E18001RG21318 meterODU-socket 4mmopen
NHC41001E20001RG21320 meterODU-socket 4mmopen

Output-Connectors / cables

Article NumberUsable forCable TypCable Length
NHC41001E02002






CAPTEC

GLOWTEC

VAPTEC

from

NHCR => Ground
(up to max. 10kV)



RG2132 meterODU-socket 4mmTube crimping lug M8
NHC41001E04002RG2134 meterODU-socket 4mmTube crimping lug M8
NHC41001E06002RG2136 meterODU-socket 4mmTube crimping lug M8
NHC41001E08002RG2138 meterODU-socket 4mmTube crimping lug M8
NHC41001E10002RG21310 meterODU-socket 4mmTube crimping lug M8
NHC41001E12002RG21312 meterODU-socket 4mmTube crimping lug M8
NHC41001E14002RG21314 meterODU-socket 4mmTube crimping lug M8
NHC41001E16002RG21316 meterODU-socket 4mmTube crimping lug M8
NHC41001E18002RG21318 meterODU-socket 4mmTube crimping lug M8
NHC41001E20002RG21320 meterODU-socket 4mmTube crimping lug M8
NHC41001E02003


VAPTEC
from
NHCR => NDRG
(up to max. 10kV)







RG2132 meterODU-socket 4mmODU-socket 4mm
NHC41001E04003RG2134 meterODU-socket 4mmODU-socket 4mm
NHC41001E06003RG2136 meterODU-socket 4mmODU-socket 4mm
NHC41001E08003RG2138 meterODU-socket 4mmODU-socket 4mm
NHC41001E10003RG21310 meterODU-socket 4mmODU-socket 4mm
NHC41001E12003RG21312 meterODU-socket 4mmODU-socket 4mm
NHC41001E14003RG21314 meterODU-socket 4mmODU-socket 4mm
NHC41001E16003RG21316 meterODU-socket 4mmODU-socket 4mm
NHC41001E18003RG21318 meterODU-socket 4mmODU-socket 4mm
NHC41001E20003RG21320 meterODU-socket 4mmODU-socket 4mm
NDC70739F01001








LITEC

--EPIC plug-
NDC41117E02003RG2132 meterEPIC plugopen
NDC41117E04003RG2134 meterEPIC plugopen
NDC41117E06003RG2136 meterEPIC plugopen
NDC41117E08003RG2138 meterEPIC plugopen
NDC41117E10003RG21310 meterEPIC plugopen
NDC41117E12003RG21312 meterEPIC plugopen
NDC41117E14003RG21314 meterEPIC plugopen
NDC41117E16003RG21316 meterEPIC plugopen
NDC41117E18003RG21318 meterEPIC plugopen
NDC41117E20003RG21320 meterEPIC plugopen
ODU-socket 4mm
3405.3
EPIC plug
NDC70739F01001

Tube Crimping lug M8