SLC TWIN PRO

 

 

 

 

 

 

 

 

Short description

Covering a wide range of powers from 700 VA to 20 kVA, J.Schneider SLC TWIN PRO series gives maximum reliability in electrical
protection for businesses and industry. With its double conversion On-line technology, the most reliable technology on the market,
the SLC TWIN PRO series is a single phase output UPS (with single phase input from 700 VA to 10 kVA and three-phase input
from 8 kVA to 20 kVA), with an output power factor of 0.9(1), broad communication options via interface + monitoring/automatic
file closing shutdown software, batteries for standard autonomy integrated in the cabinet itself, option of extending back-up for
processes requiring greater available autonomy and options of parallel/redundant operation up to 4 units(1) for installations growing

in qualitative and quantitative demands.

 

Added performances include the standard static and maintenance bypasses(1), the low input current distortion (THDi) under 5%, small
footprint in both standard and extended autonomies, full information obtained from the LCD/graphic display or the possibility of working in

frequency converter mode.

 

Technical Data

Model TWIN PRO 0,7 ÷ 3 kVA TWIN PRO 4 ÷ 10 kVA TWIN/3 PRO 8 ÷ 20 kVA
FORMAT Tower
TECHNOLOGY On-line, double conversion, PFC with double DC bus
INPUT Nominal voltage 200 / 208 / 220 / 230 / 240 V (1) 3 x 380 / 400 / 415 V
  Voltage range 110 ÷ 300 V (2) 110 ÷ 276 V (2) 3 x 190÷478+N (2)
  Frequency 50 / 60 Hz
  Frequency range ± 10%
  Power factor ≥ 0,99
  Total Harmonic Distortion (THDi) <5%
OUTPUT Power factor 0,8 0,9
  Nominal voltage 200 / 208 / 220 / 230 / 240 V (1)
  Voltage accuracy ± 2% ± 1%
  Maximum slew rate 1 Hz/s
  Frequency
synchronisation

mains present  

± 10%
  free running ± 0,2 Hz ± 0,1 Hz ± 0,05 Hz
  Efficiency >88% 92% >93%
  Total Harmonic Distortion (THDv) (2) ≤3% linear load;
≤5% non-linear load
(according to EN 62040-3)
≤2% linear load;
≤5% non-linear load
(according to EN 62040-3)
  Admissible overload
(normal mode)
Up to 110% during 1 min;
125% during 30 s
Up to 125% during 2 min;
150% during 30 s
Up to 110% during 5 min;
130% during 1 min
  Crest factor 3 to 1
  Parallel Nein Yes, up to 4 units

 

(1) Power reduction for 200 V and 208 V versions in single-single units and only for 200 V in three-single

(2) With load at 50%

(3)Power reduction of 40% in single-single models

(4) 8 kVA and 10 kVA <55 dB

More details see flyer.

Downloads

Description
Version
File Format

Flyer SLC TWIN PRO

-PDF
Manual 0,7 ... 3 kVA-PDF
Manual 4 ... 20 kVA-PDF

To download the manuals please log in here