CAPTEC 2-40kV/ 1000-10000J/sec

The clocked high-voltage power supply CAPTEC was especially designed for the requirements for the charge of capacitors. It is available with charging Ratings of 1.000J/sec, 10.000J/sec, 2500J/sec and 5000J/sec in nine different output voltages from 2kV up to 40kV. The charging voltage and the charging current can be adjusted independently and the actual values are read out via the analogue Interface. The charging procedure is started with the release, the voltage. After the release the charging process starts, the voltage of the charged capacitor rises linear up to the adjusted nominal value. If the nominal value for the voltage is reached, a HV-Ok signal is transmitted via the interface respectively the LED “C full” in the front plate illuminates. If the trickle charging is activated at the unit, the unit is charged if the voltage drops to an adjusted threshold. In this way, the voltage of the charged capacitor remains constant. Then the power supply recognizes if the capacitor is discharged abruptly and starts the charging process by itself.Optionally a touch panel is deliverable for the CAPTEC. The devices can be delivered with positive or with negative polarity.

SPECIFICATION

Input400Vac ±10%, 50 or 60Hz, three phase
Output44 models from 2kV up to 40kV with a charge power of 1.000J/sec to 10.000J/sec. Every model is available with positiv or negative polarity. Output voltages up to 5kV are optionally available with potential-free output.
Current regulation

Load: 0,1% of full current for any voltage change.
Line: : ± 0,1% of full current over specified input range.

CoolingUp to 10 kW air-cooled> 10 kW water-cooled
InsulationUp to 20kV air-insulated> 20kV oil isolated
Interface

Analogue/digital I/O: The nominal values for output voltage, output current and output rating can be adjusted and the actual values for output voltage, output current and output rating can be read out. Additionally the release of the power element / output voltage can be set and the information about error, HV ok and cooling phase of the arc limitation can be read out.

RS232: With the RS232 interface the nominal values for output voltage, -current and -rating can be adjusted and the corresponding actual values can be read out. Additionally the release can be activated and error messages can be read out. Furtherer adjustment respectively the parameterization of the unit is possible.

CE MarkEN55011/03.91 (Limit value class A)
EN50082-2/03.95

SELECTION TABLE

Maximum RatingModul Number
kV DCmAJ/sec
210001000CAPTEC 0021k0
215001500CAPTEC 0021k5 
225002500CAPTEC 0022k5
250005000CAPTEC 0025k0
36661000CAPTEC 003666
310001500CAPTEC 0031k0
316662500CAPTEC 0031k6
333335000CAPTEC 0033k3
54001000CAPTEC 005400
56001500CAPTEC 005600
510002500CAPTEC 0051k0
520005000CAPTEC 0052k0
82501000CAPTEC 008250
83751500CAPTEC 008375
86252500CAPTEC 008625
812505000CAPTEC 0081k2
102001000CAPTEC 010200
103001500CAPTEC 010300
105002500CAPTEC 010500
1010005000CAPTEC 0101k0
151321000CAPTEC 015132
152001500CAPTEC 015200
153332500CAPTEC 015333
156665000CAPTEC 015666
20501000CAPTEC 020100
201501500CAPTEC 020150
202502500CAPTEC 020250
205005000CAPTEC 020500
25801000CAPTEC 025080
251201500CAPTEC 025120
252002500CAPTEC 025200
254005000CAPTEC 025400
30661000

CAPTEC 030066

301001500CAPTEC 030100
301662500CAPTEC 030166
303335000CAPTEC 030333
305007500CAPTEC 030500
3066610000CAPTEC 030666
40501000CAPTEC 040050
40751500CAPTEC 040075
401252500CAPTEC 040125
402505000CAPTEC 040250
403757500CAPTEC 040375
4050010000CAPTEC 040500